mirror of https://github.com/OpenIdentityPlatform/OpenDJ.git

Christophe Sovant
05.26.2008 c14e6cb01ca2b8624d4c133f6f109c17510f90a6
opends/tests/functional-tests/testcases/snmp/snmp_status.xml
@@ -467,35 +467,15 @@
              </call>
              <message>
                'status: disable the SNMP Connection Handler'
                'status: restart the SNMP Connection Handler'
              </message>
              <call function="'dsconfig'">
              <call function="'restartSNMPConnectionHandler'">
                {
                'dsInstanceHost'   : DIRECTORY_INSTANCE_HOST ,
                'dsInstancePort'   : DIRECTORY_INSTANCE_PORT ,
                'dsInstanceDn'     : DIRECTORY_INSTANCE_DN ,
                'dsInstancePswd'   : DIRECTORY_INSTANCE_PSWD ,
                'subcommand'       : 'set-connection-handler-prop' ,
                'objectType'       : 'handler-name' ,
                'objectName'       : 'SNMP Connection Handler' ,
                'optionsString'    : '--set enabled:true'
                }
              </call>
              <message>
                'status: enable the SNMP Connection Handler'
              </message>
              <call function="'dsconfig'">
                {
                'dsInstanceHost'   : DIRECTORY_INSTANCE_HOST ,
                'dsInstancePort'   : DIRECTORY_INSTANCE_PORT ,
                'dsInstanceDn'     : DIRECTORY_INSTANCE_DN ,
                'dsInstancePswd'   : DIRECTORY_INSTANCE_PSWD ,
                'subcommand'       : 'set-connection-handler-prop' ,
                'objectType'       : 'handler-name' ,
                'objectName'       : 'SNMP Connection Handler' ,
                'optionsString'    : '--set enabled:true'
                'dsInstancePswd'   : DIRECTORY_INSTANCE_PSWD
                }
              </call>
@@ -583,7 +563,7 @@
              <script>
                msg1 = 'An unexpected error occurred while trying to initialize'
                msg2 = 'the SNMP Connection Hanlder. Please check the'
                msg2 = 'the SNMP Connection Handler. Please check the'
                msg3 = 'configuration attributes'
                msg = '%s %s %s' % (msg1, msg2, msg3)
              </script>
@@ -668,7 +648,55 @@
              </call>
              <message>
                'status: disable the SNMP Connection Handler'
                'status: restart the SNMP Connection Handler'
              </message>
              <call function="'restartSNMPConnectionHandler'">
                {
                'dsInstanceHost'   : DIRECTORY_INSTANCE_HOST ,
                'dsInstancePort'   : DIRECTORY_INSTANCE_PORT ,
                'dsInstanceDn'     : DIRECTORY_INSTANCE_DN ,
                'dsInstancePswd'   : DIRECTORY_INSTANCE_PSWD
                }
              </call>
              <call function="'testCase_Postamble'"/>
            </sequence>
          </testcase>
          <!--- Test Case information
            #@TestMarker          SNMP Connection Handler status
            #@TestName            status: check error message and status when
                                  the listen-port property is set to a wrong
                                  value
            #@TestIssue           none
            #@TestPurpose         Check error message and status when
                                  the listen-port property is set to a wrong
                                  value.
            #@TestPreamble        none
            #@TestStep            set listen-port property to a wrong value
            #@TestStep            restart the server
            #@TestStep            check that an error message is displayed at
                                  startup
            #@TestStep            check status using status command
            #@TestStep            restore value for listen-port property
            #@TestStep            disable the SNMP connection handler
            #@TestStep            enable the SNMP connection handler
            #@TestPostamble       none
            #@TestResult          Success if an error message is displayed and
                                  if the output of status is correct.
          -->
          <testcase name="getTestCaseName
          ('status: status with a wrong listen-port value')">
            <sequence>
              <call function="'testCase_Preamble'"/>
              <message>
                'status: set the listen-port to a wrong value'
              </message>
              <call function="'dsconfig'">
@@ -680,12 +708,94 @@
                'subcommand'       : 'set-connection-handler-prop' ,
                'objectType'       : 'handler-name' ,
                'objectName'       : 'SNMP Connection Handler' ,
                'optionsString'    : '--set enabled:true'
                'optionsString'    : '--set listen-port:%s' \
                                     % DEFAULT_PROPERTIES['listen-port']
                }
              </call>
              <message>
                'status: enable the SNMP Connection Handler'
                'status: restart DS running on port %s' \
                % (DIRECTORY_INSTANCE_PORT)
              </message>
              <call function="'StopDsWithScript'">
                {
                'location'  : STAF_REMOTE_HOSTNAME ,
                'dsHost'    : DIRECTORY_INSTANCE_HOST ,
                'dsPort'    : DIRECTORY_INSTANCE_PORT ,
                'dsBindDN'  : DIRECTORY_INSTANCE_DN ,
                'dsBindPwd' : DIRECTORY_INSTANCE_PSWD
                }
              </call>
              <call function="'StartDsWithScript'">
                { 'location' : STAF_REMOTE_HOSTNAME }
              </call>
              <script>
                returnString = STAXResult[0][1]
              </script>
              <!--- Check that DS started -->
              <call function="'isAlive'">
                {
                'noOfLoops'        : 5 ,
                'noOfMilliSeconds' : 2000
                }
              </call>
              <script>
                msg1 = 'An unexpected error occurred while trying to initialize'
                msg2 = 'the SNMP Connection Handler. Please check the'
                msg3 = 'configuration attributes'
                msg = '%s %s %s' % (msg1, msg2, msg3)
              </script>
              <call function="'checktestString'">
                {
                'returnString'   : returnString ,
                'expectedString' : msg
                }
              </call>
              <message>
                'status: status when the server is started'
              </message>
              <call function="'StatusWithScript'">
                {
                'dsBindDN'  : DIRECTORY_INSTANCE_DN ,
                'dsBindPwd' : DIRECTORY_INSTANCE_PSWD
                }
              </call>
              <script>
                returnString = STAXResult[0][1]
              </script>
              <call function="'checktestString'">
                {
                'returnString'   : returnString ,
                'expectedString' : '0.0.0.0:%s  : SNMP     : Enabled' \
                                   % DEFAULT_PROPERTIES['listen-port']
                }
              </call>
              <message>
                'status: get request'
              </message>
              <call function="'SNMPGet'">
                {
                'snmpVersion'   : '1',
                'snmpHost'      : DIRECTORY_INSTANCE_HOST ,
                'snmpPort'      : SNMP_PORT ,
                'snmpCommunity' : community ,
                'snmpOIDs'      : oid ,
                'snmpStatus'    : 'reqTimeout'
                }
              </call>
              <message>
                'status: restore value for listen-port property'
              </message>
              <call function="'dsconfig'">
@@ -697,7 +807,21 @@
                'subcommand'       : 'set-connection-handler-prop' ,
                'objectType'       : 'handler-name' ,
                'objectName'       : 'SNMP Connection Handler' ,
                'optionsString'    : '--set enabled:true'
                'optionsString'    : '--set listen-port:%s' \
                                     % SNMP_PROPERTIES['listen-port']
                }
              </call>
              <message>
                'status: restart the SNMP Connection Handler'
              </message>
              <call function="'restartSNMPConnectionHandler'">
                {
                'dsInstanceHost'   : DIRECTORY_INSTANCE_HOST ,
                'dsInstancePort'   : DIRECTORY_INSTANCE_PORT ,
                'dsInstanceDn'     : DIRECTORY_INSTANCE_DN ,
                'dsInstancePswd'   : DIRECTORY_INSTANCE_PSWD
                }
              </call>